How to Check Solar Panel Polarity With a Multimeter

Before you plug solar panels into anything, you should verify which connector is positive and negative using a multimeter.

Summary

Set the meter to DC volts (V⎓) on the 200 V range, black lead in COM and red in the volts jack. With the panel in light and its leads connected to nothing, touch a probe to the contact in each connector. A plain reading means the red probe is on positive; a minus sign means it is on negative.

What you need

As an Amazon Associate I earn from qualifying purchases.

  • Digital multimeter

    AM33D digital multimeter, 2000 counts

Prices are subject to change.

Before You Start

Why Not Just Read the Markings?

Markings can be wrong, and an adapter cable can swap the leads. The meter is the proof.

A plus sign moulded into a connector, a red sleeve or a sticker only tells you what somebody intended. An extension or adapter cable between the panel and the controller can swap the two leads over, and nothing on the outside of the cable shows it — which is why the check comes before anything is connected.

Step 1

Set the Meter to DC Volts (V⎓), 200 V Range

Turn the dial to DC volts — the V⎓ symbol — and to the 200 V range on a manual meter.

A solar panel makes direct current, so the meter has to be on its DC volts setting. The symbol is a V with a straight line over a dashed line (V⎓). The V with a wavy line (V∼) is AC volts, which is for wall sockets and reads nothing useful here.

Then the range. On a manual meter, pick one above the voltage on the panel's label: the label lists an open-circuit voltage, usually written Voc, and for one or two 100 W panels — about 22–25 V — that is the 200 V range. The 20 V range is below that and over-ranges. An auto-ranging meter picks the range itself, so there is nothing to set.

Step 2

Black Lead in COM, Red Lead in the Volts Jack

Black lead in COM. Red lead in the volts jack, not the amps jack.

The black lead always goes in the jack marked COM. The red lead goes in the jack marked with a V. Most meters have a second or third red jack marked A or 10A for measuring current. Leave it empty.

Never the amps jack

In the amps jack, the meter is a short circuit across the panel. If the red lead is in that jack when the probes touch the panel's two leads, the panel is shorted through the meter. Look at where the red plug is before every measurement, not just the first one.

Step 3

Put the Panel in the Light With Its Leads Free

Put the panel in the light, with its leads connected to nothing.

A panel only makes voltage when light falls on it. Face down, covered or indoors it reads close to zero, and a reading close to zero tells you nothing about polarity. Daylight is enough; it does not have to be full sun.

Both leads should be lying free: not plugged into a controller, a battery, another panel or each other. You are measuring the panel on its own.

Step 4

Touch One Probe to the Contact Inside Each Connector

Touch one probe to the metal contact inside each connector.

Each MC4 connector has a metal contact set back inside its plastic housing. Reach one probe tip in to the contact of one connector and the other probe tip in to the contact of the other. It does not matter which probe goes to which connector: the display tells you in the next step.

Hold the probes by their insulated handles, and keep the two probe tips from touching each other.

Step 5

Read the Sign in Front of the Number

A plain number means the red probe is on positive. A minus sign means the probes are reversed, and red is on negative.

The size of the number matters less than the sign in front of it. No minus sign: the lead under the red probe is positive. A minus sign: the lead under the red probe is negative, and the lead under the black probe is the positive one. Swap the probes if you want to see it confirmed; the same number comes back without the minus.

As an example, the label of a 100 W panel in our catalogue (Renogy RNG-100D-SS 100 W 12 V monocrystalline panel) lists an open-circuit voltage of 24.3 V, so in good light the display shows a number near 24.3 or -24.3. That figure is a panel's open-circuit voltage, read from a catalogue record of its label. It is not a charge voltage and not a controller setting. Your panel has its own figure on its own label, and in weaker light the reading is lower.

If the display flickers around zero, the panel is not getting enough light or a probe is not on the metal contact.

Step 6

Mark the Positive Lead, Then Check the Far End

Mark the positive lead. Then check again at the far end of your cable, before it goes near a controller.

Wrap a band of red tape around the positive lead as soon as you have found it, so the answer does not depend on your memory.

If an extension cable runs between the panel and the controller, plug it in and repeat the check at its far end. That end is the one that gets connected, and it is the cable in between that can swap the leads. Mark the positive lead there as well.

The Common Question

Which MC4 Is Positive?

Meter it. Do not trust the housing.

An MC4 housing tells you one thing: whether the connector is male or female. It does not tell you which conductor was crimped into it. That was decided by whoever assembled the lead, and every cable added between the panel and the controller is another place where the two can be swapped.

So there is no rule about housings on this page. The polarity of a lead is whatever the meter reads at the end you are about to connect, and the six steps above are how you read it.

Safety

Panels in Series Are Not Low Voltage

One small panel is low voltage. Panels wired in series are not, so keep your fingers off the metal.

Series strings add up

When panels are wired in series, each one adds its voltage to the string, and the string is live whenever there is light on it. Treat the contacts of a series string as you would any live conductor: probes held by their insulated handles, fingers off the metal contacts, and nothing else connected while you measure.

The same habit applies on the vehicle side. Before a controller's output goes anywhere near a charge port, the charger plug that port normally sees is metered the same way: DC volts, black in COM, red in the volts jack, and read the sign. Our guide to reading and metering an e-bike charge port covers that half, and the MC4 crimping guide covers making the lead you have just tested. Both are linked below.

FAQ

Common Questions

Which MC4 connector is positive on a solar panel?

The one your multimeter says is positive. An MC4 housing tells you whether a connector is male or female, not which conductor was crimped into it, and an extension or adapter cable can swap the two leads over. Set the meter to DC volts (V⎓) on the 200 V range, put the panel in the light and touch one probe to the contact inside each connector: a plain reading means the red probe is on the positive lead.

What does a minus sign on the multimeter mean?

The probes are the opposite way round to the voltage: the red probe is on the negative lead and the black probe is on the positive one. Nothing is wrong with the panel or the meter. Swap the probes and the same number comes back without the minus sign.

Why must the red lead not be in the amps jack?

In the amps jack the meter is a short circuit between its two probes, because that is how it measures current. Touch those probes to a panel's two leads and you have shorted the panel through the meter. That is the mistake that costs a meter. For a polarity check the red lead goes in the volts jack and stays there.

What happens if a solar panel is connected backwards?

A reversed connection can damage a charge controller. Some controllers are protected against it and some are not, and the box does not always say which. The check on this page takes about thirty seconds, so do it before the panel is connected to anything rather than finding out afterwards.

Do I need to check polarity on a ready-made extension cable?

Yes, at the far end of it. A cable that is correct at the panel can still arrive at the controller with its leads swapped, because adapter and extension cables are not all wired the same way. Repeat the check at the end that will actually be connected, and mark the positive lead there too.

Is it safe to touch the contacts while testing?

One small panel is low voltage. Panels wired in series are not: each panel adds its voltage to the string. Either way, hold the probes by their insulated handles and keep your fingers off the metal contacts. The panel makes voltage whenever light falls on it, so a lead is live as soon as the panel is in the sun.